Sub Zero Appliance Repair Error Codes
Many Sub Zero appliances have self diagnostic features.
These Error Codes could be helpful for you to determine what is wrong with your Sub Zero:
400 SERIES WINE STORAGE
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures may vary.
55 SERVICE (Flashing) EE————————Upper compartment thermistor fault
BELL ON (Flashing)
55 SERVICE (Flashing) EE————————-Upper compartment thermistor fault with temperature alarm
EE SERVICE (Flashing) 55 ————————Lower compartment thermistor fault
BELL ON (Flashing)
EE SERVICE (Flashing) 55————————-Lower compartment thermistor fault with temperature alarm
55 SERVICE (Flashing) 55————————-Either evaporator thermistor fault
BELL ON (Flashing)
55 SERVICE (Flashing) 55————————-Either evaporator thermistor fault with temperature alarm
NOTE: Cooling functions are disabled when error indicators appear.
400 SERIES, MODEL 427R REFRIGERATOR
Possible Error Indicators
NOTE: Temperature shown is for reference only, actual temperature may vary.
TOP DRAWER (Flashing)
EE LOWER DRAWER (Flashing) ———————————————-Refrigerator compartment thermistor fault
TOP DRAWER (Flashing)
40 LOWER DRAWER (Flashing) ————————————————Refrigerator evaporator thermistor fault.
E0
700BR & 700BF Communication Error between ————————————–Control Board & Control Panel
E3
700BR & 700BF Communication Error between ————————————-Control Board & Control Panel
400-2 SERIES WINE STORAGE
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures may vary.
55 SERVICE (Flashing) EE —————————————————————Upper compartment thermistor fault
BELL ON (Flashing)
55 SERVICE (Flashing) EE ————————–Upper compartment thermistor fault with temperature alarm
EE SERVICE (Flashing) 55 —————————————————————Lower compartment thermistor fault
BELL ON (Flashing)
EE SERVICE (Flashing) 55 —————————-Lower compartment thermistor fault with temperature alarm
55 SERVICE (Flashing) 55 ——————————————————————–Either evaporator thermistor fault
BELL ON (Flashing)
55 SERVICE (Flashing) 55 ———————————Either evaporator thermistor fault with temperature alarm
NOTE: Cooling functions are disabled when error indicators appear.
400-2 SERIES WINE STORAGE
CODE INDICATION
05 Upper Cabinet Thermistor read open / short for 10+ seconds, or repeatedly erratic tempís.
06 Upper Evap. Thermistor read open / short for 10+ seconds, or repeatedly erratic tempís.
07 Lower Cabinet Thermistor read open / short for 10+ seconds, or repeatedly erratic tempís.
08 Lower Evap. Thermistor read open / short for 10+ seconds, or repeatedly erratic tempís.
10 Upper Cabinet Warm Temperature alarm
11 Upper Cabinet Cold Temperature alarm
12 Lower Cabinet Warm Temperature alarm
13 Lower Cabinet Cold Temperature alarm
15 Sealed System Fault (evap temp. cannot drop 5∞ in 5 minutes, 3 consecutive valve activations)
400-2 SERIES – 427R-2 REFRIGERATOR CODE INDICATION
05 Upper Cabinet Thermistor read open / short for 10+ seconds, or repeatedly erratic tempís.
50 Excessive Refrigerator compressor run
600 SERIES (Prior To Serial #1810000)
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures may vary.
EE SERVICE (Flashing) 38 ————————————————————–Freezer compartment thermistor Fault
00 SERVICE (Flashing) EE ——————————————————–Refrigerator compartment thermistor fault
00 SERVICE (Flashing) 38 ————————————————————–Refrigerator evaporator thermistor fault
SERVICE (Flashing)
00 ICE (Flashing) 38 —————–Water valve energized longer than 15 seconds. Icemaker system disabled.
NOTE: A 45 minute dwell follows each IM cycles (no power to Icemaker). To bypass 45 minute dwell, Switch unit OFF then back ON.
SERVICE (Flashing)
12 VACUUM (Flashing) 45————————————-CONDENSER:Several excessive compressor run periods
600 SERIES (Starting With Serial #1810000)
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures may vary.
EE SERVICE (Flashing) 38 —————————————————————–Freezer compartment thermistor fault
00 SERVICE (Flashing) EE ———————————————————Refrigerator compartment thermistor fault
00 SERVICE (Flashing) 38 ————————————————–Several excessive compressor run periods OR—————————————————-Refrigerator evaporator thermistor fault
SERVICE (Flashing)
00 ICE (Flashing) 38 —————Water valve energized longer than 15 seconds. Icemaker system disabled.
NOTE: A 45 minute dwell follows each IM cycles (no power to Icemaker). To bypass 45 minute dwell, Switch unit OFF then back ON.
CODE INDICATION
05 Refrig. Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic tempís
06 Refrig. Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic tempís
07 Freezer Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic tempís
08 Freezer Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic tempís
20 Defrost Underheat with No Voltage Feedback Through Gray/White Wire at Defrost Start
21 Defrost Overheat
22 No Voltage Feedback Through Gray/White Wire at Defrost Start
23 Defrost Overheat with No Voltage Feedback through Gray/White Wire at Defrost Start
24 Defrost Underheat
600-2 SERIES
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures may vary.
EE SERVICE (Flashing) 38 —————————————————————Freezer compartment thermistor fault
00 SERVICE (Flashing) EE ———————————————————-Refrigerator compartment thermistor fault
00 SERVICE (Flashing) 38 ————————————————-Several excessive compressor run periods OR———————————————————Refrigerator evaporator thermistor fault
SERVICE (Flashing)
00 ICE (Flashing) 38 ——————————-Water valve energized longer than 15 seconds, five consecutive——————————————–times. Icemaker system disabled 24 hours each time.
NOTE: A 45 minute dwell follows each IM cycles (no power to Icemaker). To bypass 45 minute dwell, Switch ice maker system OFF then back ON.
00 SERVICE (Steady, not Flashing)38 ————————–Error Codes logged and observed but not cleared.
CODE INDICATION
05 Ref. cabinet therm. read open, short or erratic temp for 10+ secís
06 Ref. evap. therm. read open, short or erratic temp for 10+ secís
07 Fre. cabinet therm. read open, short or erratic temp for 10+ secís
08 Fre. evap. therm. read open, short or erratic temp for 10+ secís
20 Defrost underheat & no feedback thru Gr/Wh wire at defrst start
21 Defrost overheat
22 No feedback thru Gr/Wh wire at defrost start
23 Defrost overheat & no feedback thru Gr/Wh wire at defrost start
24 Defrost underheat
30 Excess IM Water Valve Solenoid Activation (> 15 Seconds)
40 Excessive Freezer Comp Run
50 Excessive Refrigerator Comp Run
700 SERIES
Possible Error Indicators
(- -) —————————————————————————- Control is shut off. Press COLDER key to start unit.
(- 20 ) ——————————————— Zone/Compartment thermistor fault. Repair wiring or replace thermistor.
( 55) —————————————– Zone/Compartment thermistor shorted. Repair wiring or replace thermistor.
(Su) —————————————————————Blue wire of display cable unhooked or faulty. Repair wiring.
(- 88 ) ———- Red Wire of display cable unhooked or faulty, top lights are off and keys are inoperative.
700-2 SERIES (Tall Units)
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures may vary.
EE SERVICE (Flashing) 38 ————————————————————–Freezer compartment thermistor Fault
00 SERVICE (Flashing) EE ——————————————————–Refrigerator compartment thermistor fault
00 SERVICE (Flashing) 38 —————————————————Several excessive compressor run periods OR———————————————————–Refrigerator evaporator thermistor fault
SERVICE (Flashing)
00 ICE (Flashing) 38 ————–Water valve energized longer than 15 seconds. Ice maker system disabled.
NOTE: A 45 minute dwell follows each IM cycles (no power to Icemaker). To bypass 45 minute dwell, Switch unit OFF then back ON.
700-2 SERIES (Tall Units)Starting W/ Serial #1759163
CODE INDICATION
05 Ref. cabinet therm. read open, short or erratic temp for 10+ secís
06 Ref. evap. therm. read open, short or erratic temp for 10+ secís
07 Fre. cabinet therm. read open, short or erratic temp for 10+ secís
08 Fre. evap. therm. read open, short or erratic temp for 10+ secís
20 Defrost underheat & no feedback thru Gr/Wh wire at defrst start
21 Defrost overheat
22 No feedback thru Gr/Wh wire at defrost start
23 Defrost overheat & no feedback thru Gr/Wh wire at defrost start
24 Defrost underheat
80 High VS compressor differential pressures or low voltage supplied to VS compressor
81 High Amperage Draw at VS compressor
82 VS comp. couldnít maintain min. speed at highest current draw
83 Locked VS compressor Rotor
84 Short circuit at VS compressor controller output circuit
85 VS compressor inverter overheated & shut down VS compressor
86 Serial communication failure between VS compressor controller and electronic control board
87 Speed information from electronic control board is out of spec.
88 Electronic control board not receiving status data in response to speed commands
NOTE: VS Compressor = Variable Speed Compressor
700-3 SERIES – TALL UNITS
CODE INDICATION
05 Ref. cabinet therm. read open, short or erratic temp for 10+ secís
06 Ref. evap. therm. read open, short or erratic temp for 10+ secís
07 Fre. cabinet therm. read open, short or erratic temp for 10+ secís
08 Fre. evap. therm. read open, short or erratic temp for 10+ secís
20 Defrost underheat & no feedback thru Gr/Wh wire at defrst start
21 Defrost overheat
22 No feedback thru Gr/Wh wire at defrost start
23 Defrost overheat & no feedback thru Gr/Wh wire at defrost start
24 Defrost underheat
30 Excess IM Water Valve Solenoid Activation (> 15 Seconds)
40 Excessive Freezer Comp Run
50 Excessive Refrigerator Comp Run
700-3 SERIES – BASE UNITS
CODE INDICATION
05 Ref. cabinet therm. read open, short or erratic temp for 10+ secís
06 Ref. evap. therm. read open, short or erratic temp for 10+ secís
07 Fre. cabinet therm. read open, short or erratic temp for 10+ secís
08 Fre. evap. therm. read open, short or erratic temp for 10+ secís
20 Defrost underheat & no feedback thru Gr/Wh wire at defrst start
21 Defrost overheat
22 No feedback thru Gr/Wh wire at defrost start
23 Defrost overheat & no feedback thru Gr/Wh wire at defrost start
24 Defrost underheat
30 NA
40 Excessive Freezer Comp Run
50 Excessive Refrigerator Comp Run